MARK Climate Technology distributor in TürkiyeElburz Mühendislik
Climate solutions for the way your building works
Start with your application, identify the need and explore suitable MARK products. Each option is assessed against the building, energy services and operating conditions.
Factories and production halls
We distinguish comfort around production lines from the process air requirement. Heating a whole hall, supporting individual workstations and summer cooling call for different product choices.
Heating zones
Identify shifts and occupied areas. Compare air heating and zonal radiant options against hall height and machine layouts.
Summer load and moisture
Assess machine heat and roof gains. Check outdoor humidity and air relief for COLDSTREAM, and cooling load and electrical capacity for MISTRAL.
Outdoor air and process
Calculate occupant outdoor air, local process extraction and replacement air separately. Recirculation fans do not replace contaminant extraction.
Selection inputs
Hall dimensions and height · Shifts · Machine heat loads · Existing gas/water/electrical services · Extract rates
Explore MARK products for these needs
GS+ / GSX
Space heating with gasSelect discharge direction, occupied zones and the flue/condensate arrangement together.
TANNER MDA / MDA+
Water-based air heatingSelect capacity at the actual water temperatures. Cooling requires a suitable model with condensate management.
MISTRAL MDX
Year-round heating and coolingAn air-to-air heat pump assessed against winter and summer loads, available electrical power and outdoor-unit placement.
COLDSTREAM
Summer cooling with outdoor airEvaporative cooling where outdoor humidity, air relief and the space’s moisture tolerance are suitable.
ECOFAN W / P140
Redistributing heat from the ceilingConsider for reducing temperature stratification in tall spaces; it does not supply outdoor air.
AIRSTREAM / AHU
Controlled outdoor-air supplyOutdoor air, filtration and suitable heat recovery are designed around airflow and duct pressure.
Product cards lead to technical comparisons, selection notes and manufacturer documents. Final selection depends on project conditions.
Warehouses and logistics facilities
Consider occupied aisles, loading doors and warm air accumulating below the roof together. The aim is to deliver air to the required aisles as well as select equipment capacity.
Racking and air distribution
Rack heights and aisle directions determine air distribution. Coordinate ECOFAN placement with racking and sprinkler layouts.
Loading doors
Record door width/height, opening times and wind exposure. An air curtain complements building pressure balance and door management.
Stored-goods conditions
Establish temperature and humidity tolerances for products and packaging. Evaporative cooling is not a default choice for moisture-sensitive stock; assess controlled cooling separately.
Selection inputs
Rack plan · Clear ceiling height · Door dimensions and daily movements · Stored goods · Target temperature/humidity
Explore MARK products for these needs
GS+ / GSX
Space heating with gasSelect discharge direction, occupied zones and the flue/condensate arrangement together.
ECOFAN W / P140
Redistributing heat from the ceilingConsider for reducing temperature stratification in tall spaces; it does not supply outdoor air.
EASYAIR T200 / T200+
Air exchange at large doorsExplore air-curtain selection for door dimensions, opening times and wind exposure.
MISTRAL MDX
Year-round heating and coolingAn air-to-air heat pump assessed against winter and summer loads, available electrical power and outdoor-unit placement.
COLDSTREAM
Summer cooling with outdoor airEvaporative cooling where outdoor humidity, air relief and the space’s moisture tolerance are suitable.
MDV BLUE
General extract ventilationSelect general extract duty using airflow and pressure calculations; specialist process extraction is designed separately.
Product cards lead to technical comparisons, selection notes and manufacturer documents. Final selection depends on project conditions.
Hangars, shipyards and maintenance areas
Large doors, moving vehicles and different workstations do not share one uniform heating requirement. Heating follows work zones, while ventilation follows the process.
Zonal comfort
Consider radiant heating for regularly occupied work zones. Crane movement, aircraft/vessel/vehicle heights and clearances to combustible materials govern placement.
Extraction and make-up air
Capture welding and blasting contaminants at source. Calculate replacement air together with pressure balance and winter heating load. CALFLO is not an extraction or filtration device.
Process suitability
Identify paint, solvent, dust and corrosive conditions separately. Do not assume standard heaters or fans suit these environments; verify equipment and placement for the project.
Selection inputs
Workstations · Door openings · Vehicle and crane movements · Process type · Local extraction rates
Explore MARK products for these needs
INFRA / INFRA HE
Radiant heating of work zonesCheck installation height, vehicles/equipment and the manufacturer’s required clearances together.
CALFLO
Replacing extracted airHeated make-up air for high extraction rates. Confirm suitability of its direct-fired design for the process.
GS+ / GSX
Space heating with gasSelect discharge direction, occupied zones and the flue/condensate arrangement together.
Product cards lead to technical comparisons, selection notes and manufacturer documents. Final selection depends on project conditions.
Sports halls and public facilities
Playing areas, spectator zones and shared spaces differ in occupancy and comfort expectations. The system should address heating, outdoor air and sound requirements together.
Heating without air jets
Consider water-supplied radiant panels for heating without air jets across occupied areas. Coordinate ceiling installation and lighting, and verify impact resistance where required.
Variable occupancy
Outdoor-air demand changes between training and events. Select heat recovery, filtration and demand-control options alongside airflow calculations.
Sound and separate spaces
Assess the hall, changing facilities and social areas separately. Coordinate fan sound, air velocity and duct attenuation; high-humidity spaces such as pools need a separate design.
Selection inputs
Occupant and spectator numbers · Operating schedule · Ceiling plan · Sound requirements · Existing water temperatures
Explore MARK products for these needs
INFRA AQUA ECO / DESIGN
Comfort heating without air jetsWater-supplied radiant ceiling panels selected for water temperatures, ceiling geometry and occupied zones.
AIRSTREAM / AHU
Controlled outdoor-air supplyOutdoor air, filtration and suitable heat recovery are designed around airflow and duct pressure.
TANNER MDA / MDA+
Water-based air heatingSelect capacity at the actual water temperatures. Cooling requires a suitable model with condensate management.
Product cards lead to technical comparisons, selection notes and manufacturer documents. Final selection depends on project conditions.
Showrooms and commercial buildings
Assess solar gains through glazing, air movement at entrances and changing occupancy together. Maintenance access and occupied-zone air velocity matter alongside appearance.
Heating and cooling
Calculate winter heat loss separately from summer solar and internal gains. Consider MISTRAL for large open showrooms, or cassette units where water services and ceiling layout suit.
Entrance comfort
Select air curtains for door size and traffic. Check air discharge towards occupied areas and external wind effects in the layout.
Outdoor air and architecture
Cassette units and heat pumps do not by themselves provide the required outdoor air. Plan heat-recovery ventilation with ceiling voids and service openings.
Selection inputs
Glazing orientation · Ceiling voids · Daily occupancy · Entrance traffic · Sound and architectural requirements
Explore MARK products for these needs
TANNER CLA
Ceiling-integrated water-based unitsAssess cassette units with ceiling voids, maintenance access and cooling condensate drainage.
EASYAIR
Air curtains for commercial entrancesChoose a model for the entrance opening and door traffic, taking building pressure balance into account.
COMPACT / FLATLINE
Compact heat recoveryAssess outdoor-air demand, duct routes and service space together.
MISTRAL MDX
Year-round heating and coolingAn air-to-air heat pump assessed against winter and summer loads, available electrical power and outdoor-unit placement.
INFRA AQUA ECO / DESIGN
Comfort heating without air jetsWater-supplied radiant ceiling panels selected for water temperatures, ceiling geometry and occupied zones.
TANNER MDA / MDA+
Water-based air heatingSelect capacity at the actual water temperatures. Cooling requires a suitable model with condensate management.
Product cards lead to technical comparisons, selection notes and manufacturer documents. Final selection depends on project conditions.
Prepare your project brief
Share your location, floor area and height, use and occupancy schedule, target temperatures, door layout and existing energy services. For process areas, add extraction rates and the nature of the work. These inputs help us assess the right combination of products.
Let’s discuss your project
Share your application and project requirements. We coordinate product selection, quotation and supply with MARK.
