MARK Climate Technology distributor in TürkiyeElburz Mühendislik

MARK products / CALFLO
MARK CALFLO · HEATED MAKE-UP AIR

CALFLO process and make-up air

Manage make-up air where substantial process extraction draws uncontrolled cold air into a facility.

MARK CALFLO gas-fired make-up air unit

How does CALFLO work?

CALFLO heats outdoor air with a directly gas-fired burner before supplying it to the facility. The burner and flame sit within the airstream, so combustion products enter the supply air. This distinguishes it from indirect-fired equipment that separates combustion gases through a heat exchanger and flue.

Its role in the system

It provides a controlled replacement-air supply for facilities with substantial extraction. Heated make-up air helps reduce the effect of cold incoming air on winter working conditions. Air distribution and the required room pressure are considered together with the extract system.

SHIPYARDS · WELDING · BLASTING HALLS

You extract the air. What replaces it?

Welding and blasting require effective extraction. But every cubic metre removed from a hall has to be replaced. If replacement air enters through open doors and gaps, its temperature and direction are difficult to control.

Replace the extracted air

CALFLO brings outdoor air into the building through a planned supply route. Local extraction continues to capture dust and fumes at their source; CALFLO provides the make-up air.

Keep winter work practical

Large halls, frequent door openings and substantial extraction make incoming cold air a real operating issue. CALFLO heats the replacement air before it reaches the working area.

Coordinate supply and extract

The supply airflow, extract airflow and target room pressure belong to one design. Coordinated controls can match operation to the process and help maintain the intended air balance.

Direct-fired heating: what enters the hall?

The burner heats the air directly, so combustion products enter the supply air. Suitability therefore depends on the application, ventilation rate, combustion conditions and applicable indoor-air limits. The design must include the required airflow and burner safety interlocks; heating alone does not establish air quality.

The solution is a coordinated air system: controlled outdoor-air supply, appropriate heating, source extraction and automation designed to work together.

Why consider it for a shipyard?

In enclosed fabrication, welding and blasting halls, the challenge is often to replace substantial process extraction without relying on uncontrolled cold draughts. CALFLO addresses that make-up-air requirement. Selection starts with the actual process and extraction duty, including any special requirements for coatings, solvents or hazardous areas.

Looking for general ventilation with heat recovery instead? Explore VERTIFLOW for high halls →

CALFLO technical data

Nominal heat input 64–896 kW; manufacturer’s series range on a lower-heating-value basis.
Burner turndown 20:1; burner capacity adjustment, not a fan airflow ratio.
Airflow · ΔT 35 K 5,430–76,080 m³/h; manufacturer’s table references 15 °C.
Airflow · ΔT 55 K 3,500–48,700 m³/h; manufacturer’s table references 15 °C.
Burner construction Modulating stainless steel line or box burner.
Casing Seawater-resistant AlMg3 aluminium; single or double skin.
Installation Indoor or outdoor configurations.
Filtration Optional HT filters; filter grade and scope are project-specific.

ΔT is the air temperature rise, not the absolute supply temperature. Airflow ranges span different models and fan selections. Final duty is verified against duct pressure, filters, outdoor conditions and required supply temperature.

Manufacturer capacity and dimensions table (PDF) ↗

How airflow affects heating duty

At the same temperature rise, more outdoor air requires more heating power. Make-up airflow and the outdoor-to-supply temperature difference therefore matter more to CALFLO selection than floor area alone.

Controls and operation

Heat input, fan operation and facility extraction involve different control functions. Burner turndown does not mean the entire system varies its airflow by the same ratio.

Fan and time-schedule options

The manufacturer’s brochure lists C10/C12 for on/off fan operation and C20/C22 for high/low operation. C12 and C22 include a clock. Panels and site connections depend on the quotation scope.

Coordination with extraction

Make-up air operation is coordinated with the relevant extraction and process schedule. Target room pressure and necessary interlocks are defined in the project controls; these are not assumed to be standard on every unit.

Maintenance access

Space is required to service filters, fans, the burner and gas equipment. Maintenance intervals follow the manufacturer’s instructions, operating hours and site conditions.

Frequently asked questions

Can it be used in a paint shop?

A paint shop first requires a controlled air supply to replace the extracted air. With CALFLO’s direct firing, combustion products and added moisture must be assessed for compatibility with the coating process. Solvent areas, unit location and required air quality need project-specific suitability confirmation from MARK; ATEX suitability must not be assumed for a standard CALFLO.

Is CALFLO an extract or dust collection system?

No. CALFLO is considered on the make-up air side. Capturing dust, fumes or vapours at source and extracting them are the functions of separate systems.

Can it be added to an existing facility?

This is assessed by reviewing the existing extract system, air inlets, energy supply and controls. Unit selection is not based on floor area alone.

Does CALFLO cool or dehumidify the air?

The CALFLO described here is a gas-fired air heating solution. Cooling or dehumidification, where needed, requires separate design provision.

Do HT filters capture process dust or solvents?

The HT filter option does not replace process exhaust treatment. Supply-air filtration and source capture of dust, fumes or solvents serve separate functions.

An initial assessment for your project

Share your application and the project information you have. If some values are not yet known, we can start with an existing specification or extract-unit details.

Elburz coordinates product selection and quotation scope with MARK. Equipment, controls, installation and commissioning scope are clearly stated in the quotation.

Request a quote

Technical source and documents

Product features are based on MARK’s CALFLO page. The brochure and original technical manual are available through the manufacturer’s page.

Source checked: 26 September 2026. The application scenario is an illustrative example prepared by Elburz; it does not promise a specific performance or saving.

ELBURZ MÜHENDİSLİK

Let’s discuss your project

Share your application and project requirements. We coordinate product selection, quotation and supply with MARK.