Complementary System Products
Resolve a missing heat-generation, heat-rejection, air-distribution or control function with equipment compatible with the main system.

Complete the system around the main unit
How does it work?
Boilers supply heat to water; dry coolers reject circuit heat to outdoor air. Controls and air distribution help deliver energy to the right zone at the right time.
Where does it fit?
Central systems, heat-pump circuits and industrial projects. Selection requires the main equipment, temperatures, flow and operating sequence.
Technical features and product options
| Group | Manufacturer features | Selection criterion |
|---|---|---|
| Dry coolers | AWS: 44–217 kW family range; copper tubes/aluminium fins; horizontal or vertical mounting with the correct kit. | Outdoor air, fluid type and temperature difference determine capacity. |
| Boilers | ECOFLEX: 115–280 kW family range; cast-aluminium heat exchanger; integrated cascade and pump control. | Check water regime, return temperature, flue and gas supply. |
| Controls | Thermostats, time/zone control and compatible BMS interfaces. Hybrid Controller: 230 V, IP54; separate PinTherm Mistral and outdoor sensor. | Match protocols and controllers to the main device; features are not standard on every product. |
| Air distribution | High-induction nozzles and textile ducts in different diameters/permeabilities. | Select airflow, pressure, throw, room geometry and maintenance provisions together. |
Ranges describe product families rather than duty at every design condition. Confirm current model availability and the selected configuration in the quotation.
AWS
Single-row dry cooler; standard and low-noise versions.
ECOFLEX
Compact high-efficiency boiler for central hot-water heating.
Hybrid Controller
Combined control of compatible heaters and MISTRAL heat pumps.
High-induction air distribution
Nozzle supply air promotes mixing with room air.
Textile air ducts
Application-specific air distribution for heating, cooling and ventilation.
Project selection and installation
Heat rejection
A dry cooler rejects heat to outdoor air; it does not produce chilled water independently of outdoor conditions like a refrigeration chiller. Define temperature approach, glycol concentration, freezing risk, flow and sound limits.
Heat generation and hydraulics
Select a boiler or HGU around circuit temperatures and load variation. Define pumps, valves, expansion, water quality and protection equipment on the system diagram; device capacity alone does not define the system.
Controls and distribution
Coordinate the control sequence, sensors, BMS signals and air distribution. Incorrect nozzle direction or textile-duct permeability may prevent a correctly sized unit from delivering the intended occupied-zone comfort.
Common questions
Are controls and accessories included automatically?
No. Device, controls, pumps, valves, ducts and site connections must be explicitly allocated in the quotation. Model compatibility and commissioning responsibilities are confirmed before supply.
Technical documents
Use the manufacturer links above for product details. Final selection is confirmed against current technical documentation and project conditions.
Product information: MARK Climate Technology and the Elburz–MARK product brochure. Product availability and options are confirmed at quotation stage.
Manufacturer manuals and product data
Sources checked: 15 November 2026. Confirm the selected configuration and operating conditions with current manufacturer documents.